Protective measures, protective equipment and emergency procedures for operators: It is recommended that emergency personnel wear portable respirators, anti-static clothing, and rubber oil-resistant gloves; it is prohibited to touch or cross the leaked material; all equipment used during operation should be grounded; cut off the source of leakage as much as possible; eliminate all ignition sources; demarcate the warning area according to the affected area of liquid flow, steam or dust diffusion, and irrelevant personnel evacuate to the safe area from the sidewind and upwind directions.
Environmental protection measures: Contain the leaked material to avoid polluting the environment. Prevent the leaked material from entering the sewer, surface water and groundwater.
Small leaks: Collect the leaked liquid in a sealable container as much as possible, absorb it with sand, activated carbon or other inert materials, and transfer it to a safe place. It is prohibited to flush it into the sewer.
Large leaks: Build a dike or dig a pit to contain it, and close the drainage pipe. Cover it with foam to inhibit evaporation, transfer it to a tank truck or a special collector with an explosion-proof pump, and recycle or transport it to a waste treatment site for disposal.